Continuous Emissions Monitoring Systems

Gas Generators and Multipoint Calibrators

Combined H2 and Zero air generator designed for to Flame Ionisation Detector based instruments

LEMAN-INSTRUMENTS designed the FID STATION 50RC product line of High Purity Hydrogen & Zero Air generators with compressor to supply independently all gases necessary to FID detector, close to the consumer in elegant 19” casing with full colour display and touchpad.

The FID Station is composed of a High purity Hydrogen generator, an Ultra Zero Air generator with on board AIR compressor:

Based on the field-proven Solid Polymer Electrolyte (PEM) cell technology, pure Hydrogen is produced at low pressure from electricity and high quality distilled water. It is available 24/7 with constant purity >99.999%. Output pressure is regulated electronically and could be set from 0.5 to 7 bar. This process can be started on demand and does not require any caustic solution.

Based on the Pressure Swing Adsorption (PSA) technology, compressed Air is first dried and filtered from pollutant gases; and then passes throughout a hot catalytic chamber to remove HC, CO, and CH4. Output pressure is regulated from 0.5 to 5 bar.

Each instrument is equipped with high performance communication interfaces USB and Ethernet (Opt) to create a very flexible gas network with local or central control.

Due to the software being focused on safety, automatic regulation and intuitive and up to date communications, the FIDSTATION 50RC is easy to install, reliable, safe and pleasant to operate.

MAIN FEATURES

  • H2and Zero Air available 24/7 at constant purity. No contamination.
  • Independent source of Hydrogen and Zero Air that does not require any piping and can be easily moved around the laboratory. Remote control from PC, smart phones and other portable devices.
  • Low noise compressor < 55dB (A)).
  • Very safe operation, internal leak-test, automatic shut-down, over-pressure valve, current and voltage limits.
  • No handling and storage of cumbersome gas cylinders. No cylinder rental fee.
  • Extended autonomy with 5L water tank.
  • Long life compressor with power economy function
  • Reduction in operation costs. Return on investment within 15 months.
  • Improves resolution and detection limit versus Helium only usage. Provides High pressure stability.

Versions

FIDSTATION50RC-100/1000: 100 Nml/ min H2 & 1000 Nml/min AIR

FIDSTATION50RC-160/2000: 160 Nml/ min H2 & 2000 Nml/min AIR

FIDSTATION50RC-250/3000: 250 Nml/ min H2 & 3000 Nml/min AIR

Purity

  • H2 >99.999% (maximum HC content: 0.05ppm)
  • AIR < 0.05 ppm HCnm; < 0.05 ppm CO and CH4

Outlet Pressure

  • H2: from 0.5 to 7 bar (7 to 100 psig), adjustable by software
  • AIR: from 0.5 to 5 bar (7 to 70 psig), adjustable by software.

Combined H2, Zero air and N2 generator designed for Gas Chromatographs

LEMAN-Instruments designed the GC STATION 60RC product line of High Purity Hydrogen, Nitrogen & Zero Air generators with compressor to independently supply all gases necessary for a FID detector and GC’s carrier in close proximity to the consumer and in an elegant 19” case, with full colour display and touchscreen.

The GC Station is composed of a High purity Hydrogen generator, an Ultra Zero Air generator with on board AIR compressor and an ultra-pure N2 generator:

Based on the field proven Solid Polymer Electrolyte (PEM) cell technology, pure Hydrogen is produced at low pressure from electricity and high quality distilled water. It is available 24/7 with constant purity >99.9999%. Output pressure is regulated electronically and could be set from 0.5 to 7 bar. This process can be started on demand and does not require any caustic solution.

Atmospheric is compressed is partially dried and filtered from HC, CO and CH4 passing throughout an hot catalytic chamber.

A first Pressure Swing Adsorption (PSA) module is drying and filtering pollutant gases; a second Pressure Swing Adsorption (PSA) module extracts N2 from compressed AIR. Output pressure are regulated from 0.5 to 5 bar.

Each instrument is equipped with high performance communication interfaces USB and Ethernet (Opt) to create a very flexible gas network with local or central control.

Due to the software being focused on safety, automatic regulation and intuitive and up to date communications, the FIDSTATION 50RC is easy to install, reliable, safe and pleasant to operate.

Main Features

  • H2, N2 and Zero Air available 24/7 at constant purity. No contamination.
  • Independent source of Hydrogen, N2 and Zero Air that does not require any piping and can be easily moved around the laboratory. Remote control from PC, IPhone and IPad
  • Low noise compressor < 55dB (A))
  • Very safe operation, internal leak-test, automatic shut-down, over-pressure valve, current and voltage limits
  • No handling and storage of cumbersome gas cylinders. No cylinder rental fee
  • Extended autonomy with 5L water tank
  • Long life compressor with power economy function
  • Reduction in operation costs. Return on investment within 15 months.
  • Improves resolution and detection limit versus Helium only usage. Provides High pressure stability.

Versions

GCSTATION50RC-70/700/700: 70 Nml/ min H2 & N2, 700 Nml/min AIR

GCSTATION50RC-100/1000/100: 100 Nml/ min H2 & N2, 1000 Nml/min AIR

GCSTATION50RC-160/2000/160: 160 Nml/ min H2 & N2, 2000 Nml/min AIR

GCSTATION50RC-250/3000/250: 250 Nml/ min H2 & N2, 3000 Nml/min AIR

Purity

  • H2 >99.9999% (maximum HC content: 0.1ppm) Dew point <-70°C
  • AIR < 0.03 ppm HCnm; < 0.03 ppm CO and CH4 Dew point <-50°C
  • N2 >99.999% (maximum HC content: 0.1ppm) Dew point <-50°C

Outlet Pressure

  • H2: from 0.5 to 7 bar (7 to 100 psig), adjustable by software.
  • AIR & N2: from 0.5 to 5 bar (7 to 70 psig), adjustable by software.

Combined ultrahigh purity Nitrogen and zero air generator designed for Photoionization Detector based instruments

LEMAN-INSTRUMENTS designed the PID STATION 50LC product line of Ultra High Purity Nitrogen & Zero Air generators with compressor to supply independently N2 & AIR for GC-FID, carrier gas for GC, close to the consumer in an elegant casing with full colour display and touchscreen. The PID Station is composed of an Ultra High Purity Nitrogen generator, an Ultra Zero Air generator and an oil free piston AIR compressor.

Compressed Air is first partially dried and then passes throughout a hot catalytic chamber to remove HC, CO and CH4. Each gas, N2 and AIR, is dried and purified or extracted by the Pressure Swing Adsorption (PSA) technology. N2 & AIR output pressures are regulated from 0.5 to 5.5 bar.

Gases are available 24/7 with constant purity >N2: 99.9995%; AIR and N2: dew point <-50°C; CO, CH4, HC< 0.05ppm. Each instrument is equipped with high performance communication interfaces, USB, RS485 as standard, (Ethernet, WLAN as options) to create a very flexible gas network with local or central control. Due to the software being focused on safety, automatic regulation and reliable communications, the PID STATION 50LC is easy to install, reliable, safe and pleasant to operate. [/av_textblock] [av_one_half first av_uid='av-3kg4p32'] [av_image src='http://aquagas.co.cr/wp-content/uploads/2015/07/PID-STATION-50LC_rev5.jpg' attachment='3770' attachment_size='full' align='center' animation='no-animation' link='' target='' styling='' caption='' font_size='' appearance='' av_uid='av-3ik3hse'][/av_image] [av_button label='Brochures' link='manually,/wp-content/uploads/brochures/PID STATION 50LC_rev5.pdf' link_target='_blank' size='medium' position='center' icon_select='no' icon='ue800' font='entypo-fontello' color='theme-color' custom_bg='#444444' custom_font='#ffffff' av_uid='av-3gm89y6'] [/av_one_half][av_one_half av_uid='av-3fjsj4u'] [av_textblock size='' font_color='' color='' av_uid='av-3dl0y66']

Main Features

  • Improves resolution and detection limit versus Helium only usage. Provides High pressure stability
  • N2 and Zero Air available 24/7 at constant purity. No contamination
  • Independent source of Nitrogen and Zero Air that does not require any piping and can be easily moved around the laboratory. Remote Control from PC, smart phones and tablets
  • Low noise compressor < 55dB (A))
  • Very safe operation, internal leak-test, automatic shut-down, over-pressure valve, current and voltage limits
  • No handling and storage of cumbersome gas cylinders. No cylinder rental fee
  • Long life compressor with power economy function.
  • Reduction in operation costs. Return on investment within 15 months
[/av_one_half]

Versions

PIDSTATION50LC-1000/1500: 1000 Nml/ min N2 & 1500 Nml/min AIR

PIDSTATION50LC-2000/3000: 2000 Nml/ min N2 & 3000 Nml/min AIR

Purity

  • H2 >99.9995%; < 0.05 ppm HCnm; < 0.05 ppm CO and CH4
  • AIR < 0.05 ppm HCnm; < 0.05 ppm CO and CH4

Outlet Pressure

  • N2: from 0.5 to 5.5 bar (7 to 80 psig), adjustable by software.
  • AIR: from 0.5 to 5.5 bar (7 to 80 psig), adjustable by software.

AERO

LEMAN-Instruments designed the AEROSTATION 20RC-CAT product line of Zero AIR Generator with on board compressor, to fit almost any type of application which needs independent supply of high purity AIR close to the consumer in an elegant 19” casing with full colour display and touchpad.

Compressed Air is filtered throughout a hot catalytic chamber to remove CO, CH4 and HC.

After the purification process, pressure is regulated by an external manual valve, between 0.5 and 5 bar. (7 to 70 psig). Models with outflows up to 20 L/min AIR are available. Each instrument is equipped with high performance communication interfaces (RS485, Ethernet) to create a very flexible gas network with local or central control.

Due to the software being focused on safety, automatic regulation and intuitive and reliable communications, the AEROSTATION are easy to install, reliable, safe and pleasant to operate.

HYDRO

LEMAN-Instruments designed the HYDROSTATION product line of Non Maintenance Ultra High Purity Hydrogen generator to aliment an FID and GC, close to the consumer in an elegant 19” casing with full colour display and touchpad.

Based on the field proven Solid Polymer Electrolyte (PEM) cell technology, pure Hydrogen is produced at low pressure from electricity and high quality distilled water. After production, H2 is dried and purified by an exclusive No Maintenance Double Column Purifier module (PSA). H2 is available 24/7 with constant purity >99.9999%. Output pressure is regulated electronically and could be set from 0.5 to 7 bar. This process can be started on demand and does not require any caustic solution.

Models with outflows of 100, 160, 250 and 500 Nml/min H2 are available.

Due to the software being focused on safety, automatic regulation and intuitive and reliable communications, the AEROSTATION 20RC-CAT are easy to install, reliable, safe and pleasant to operate.

NITRO

LEMAN-Instruments designed the NITROSTATION50RC product line of Ultra High Purity Nitrogen Generator with integrated Air compressor, to fit almost any type of application which needs independent supply of HC free pure Nitrogen close to the consumer in an elegant 19” casing with full colour display and touchpad.

Compressed Air is first filtered from particulates down to 5μm and dried by a static dryer. Based on the field proven Pressure Swing Adsorption (PSA) technology, Nitrogen is extracted from a set of filters filled up with CMS. After the extracting process, N2 passes throughout a hot catalytic chamber to remove the last traces of organic compounds, is then stored in a buffer and filtered of remaining particulates down to 0.1μm; finally output pressure is regulated electronically to the set value, between 0.5 and 5 bar.

Models with outflows of 100, 200, 500 and 1000 Nml/min N2 are available. Each instrument is equipped with high performance communication interfaces (USB, RS485, Ethernet, and WLAN) to create a very flexible gas network with local or central control.

Due to the software being focused on safety, automatic regulation and reliable communications, the NITRO High Purity Nitrogen Generators modules are easy to install, reliable, safe and pleasant to operate.

LEMAN-Instruments designed the Dilution Multipoint Calibration Station (MCSD) product line, to fit almost any type of application which needs high precision gas mixture based on diluting high concentration mixture with integrated Zero Air generator (option).

Based on the two calibration curves of MFC1 and MFC2, as well as the pre-mixture composition, the integrated microcontroller adjusts the MFCs’ outflows to reach the expected final mixture. In order to aliment MFC1 with fresh gas, before calibration phases, a purge cycle is processed.

The Carrier gas, Zero Air, is generated from external source or internally (optional). If it is generated internally, first AIR is compressed from ambient Air and then filtered from pollutants by a set of self-regenerative filters (PSA) and a catalysis oven (option). To monitor the pre-mixture internal cylinder pressure, a high pressure sensor is attached to it and the value is read and treated by the dilutor’s electronics. In case of low pressure and lack of alimenting gases, the internal controller alarms the host system. Each instrument is equipped with high performance communication interfaces (RS485, Ethernet) to create a very flexible gas network with local or central control.

Due to the software being focused on safety, automatic regulation and intuitive and reliable communications, the Dilution Multipoint Calibration Station (MCSD) are easy to install, reliable, safe and pleasant to operate.

Main Features

  • Minimum gas consumption
  • Remote control from PC, IPhone and IPad
  • 4.3” TFT-LCD colour display with touchpad
  • Provides High pressure stability
  • Up to three Pre-mixture gases inlet
  • Cylinders pressure measured
  • Built in Zero Air Generator (option)

Outflows

  • 750 to 1500 Nml/min mixture during calibration phase
  • 100 to 1500 Nml/min ZERO AIR during Zeroing phase

Dilution ratio

  • 1/20 to 1/450, by flow variations of diluted gas

Inlet concentration range

  • From 1 ppm to 100ppm

Precision / Repeatability

  • Better than +/- 1% relative
  • Better than +/- 0.7% relative

LEMAN-Instruments designed the modular Multipoint Permeation Calibrator (MPC) product line, to fit almost any type of application which needs high precision gas mixture based on permeation tubes.

In order to keep in equilibrium the permeation tube, the oven’s temperature is regulated at +/-0.05°C and is under a constant flow (50 to 80 ml/min) of standard quality (4.5) carrier gas made by MFC1. Between calibrations, the high concentration and low flow mixture is directed through a 3/2 valve (V2) to the purge outlet.

When the calibration is started, MFC1 is then alimented by high purity carrier gas, V1 switched to CO2 6.0; later V2 is also switched on and the high concentration mixture is injected in the carrier gas flow generated by MFC2. Based on the two calibration curves of MFC1 and MFC2, as well as the tube’s permeation rate, the integrated microcontroller adjusts the MFC2’outflow to reach the expected final mixture.

In case of lack of carrier gas, eventual malfunctioning of the oven, and before the life time end of permeation tube, the internal controller alarms the host system. Each instrument is equipped with high performance communication interfaces (RS485, Ethernet, and WLAN) to create a very flexible gas network with local or central control.

Main Features

  • Minimum carrier gas consumption
  • Remote control from PC, iPhone and iPad
  • 4.3” TFT-LCD colour display with touchpad
  • Provides High pressure stability
  • Cylinders pressure measured

Outflows

  • 500 to 5000 Nml/min of mixture during calibration
  • 50 to 80 Nml/min high concentration mixture rest of time

Versions

MPC – ST: for Hydrocarbons, BTEX

MPC – HC: for SO2, NO2, NH3, HCl, ACETALDEHYDE, COS

Concentration

  • From 10 ppb to 500ppb, depending on the permeation tube

Precision / Repeatability

  • Better than +/- 1% relative
  • Better than +/- 0.7% relative

CO2 consumption

  • 500 to 5000 Nml/min CO2 6.0 during calibration phase
  • 50 to 80 Nml/min CO2 4.5 rest of time

Silent Oil Free Compressor Unit

The Silent Oil free Air Compressor Unit, CAS1, is a plug-and play, ready to use AIR compressor unit, designed especially for laboratories and for alimenting AEROs and NITROs gas generators manufactured by LEMAN-INSTRUMENTS.

This small compressor unit is built into a ventilated and portable case with the dimensions of 400x335x320 mm.

When the calibration is started, MFC1 is alimented by high purity carrier gas, V1 switched to CO2 6.0; later V2 is also switched on and the high concentration mixture is injected in the carrier gas flow generated by MFC2. Based on the two calibration curves of MFC1 and MFC2, as well as the tube’s permeation rate, the integrated microcontroller adjusts the MFC2’outflow to reach the expected final mixture.

In case of lack of carrier gas, eventual malfunctioning of the oven and before the life time end of permeation tube, the internal controller alarms the host system. Each instrument is equipped with high performance communication interfaces (RS485, Ethernet, and WLAN) to create a very flexible gas network with local or central control.

Main Features

  • Extremely low noise level, as low as a refrigerator one meter away
  • 100 % continuous operation up to 40 °C ambient temperature.
  • Can be easily moved around the laboratory. No handling, No storage. No cylinder rental fee.
  • NO regular maintenance
  • Oil-free compressor unit
  • Integrated Pressure regulator and pressure gauge
  • Pressure switch. Start/Stop compressor on flow demand.
  • Automatic condensate drain

Single and combined High Technology Gas generator stations

FTIR, FID, Gas Chromatograph and many other type of gas analysers require the supply of specific high purity gases as zero gas (zero reference or background), carrier gas or combustion gas. These gases can be supplied from gas cylinders introducing variables in the system since the quality and purity of a same component will vary from one cylinder to the other. Gas cylinders also increase the operating cost (consumables and labour) related to a system.

In many cases, the use and integration of single or combined gas generator in the CEMS will improve the quality and the efficiency of the system in terms of operation and accuracy.

LEMAN Instruments generators lines of Hydrogen, Nitrogen, air and zero air generators have been designed to fit most applications in the field of laboratory, air quality monitoring, special realisations and OEM.

Each instrument is equipped with high performance communication interfaces allowing to realise very flexible gas networks with either local or central control. The control software handles all safety functions, the automatic pressure regulation functioning status and ensures reliable communications.

Each gas can be generated individually or combined into the same generator modules are easy to install, reliable, safe and pleasant to operate. Various level of purity can be achieved allowing keeping this “add-on” cost effective and available for a large field of applications.

Permeation and Dilution Multipoint Calibrators

Compliance monitoring systems often require automatic calibration check on a daily or weekly basis. In addition to the calibration checks a proper instrument calibration and linearity check must be conducted 6 monthly or yearly. To perform a linearity test for each gas and at five different concentrations it would be very expensive to have separate gas bottles for each test. It is also very time consuming to manoeuvre such a large quantity of bottles.

A gas dilution calibrator makes the job much easier. These five reference materials can be obtained from different gas cylinders or can be prepared by means of a calibrated dilution system from one single gas concentration. So in essence, the CEMS & AQMS operator will only need to carry as many bottles that represent each of the gases. In most cases these cylinders are already kept on site and connected to the system as they are used for the daily (or weekly) calibration checks.

Applications

Air Quality Monitoring Station
Continuous Emission Monitoring System
Laboratories
Combustion gas for FID and GC
Zero gas for HC calibrators
Carrier gas for permeation tu be systems
Combustion, carrier and make up gases for GC and GC/MS
ICP, ELSD, CORONA, PID
Protection gas for cell culture
Carrier gas for calibrators
N2 Generators for AGILENT 6400 Triple Quad LC/MS
Nebulizer and Druing gas
Collision cell gas
N2 + Zero AIR Generator for AB-SCIEX 3200 to 5500 LC/MS (curtain, source and exhaust gases)
N2 + ZERO AIR Generator for BRUKER EVOQ TQ LC/MS (source and Exhaust gases)
Nebulizing, shealth and drying gas for LC/MS
Solvent Evaporator
Life science researches
Independant Source of air for Laboratories and Gas Generators

CEMS product line

Gas sampling

Gas conditioner

Analyser

DAHS

Stack sampler

CEMS Universal components

PEMS product line

Portable sampling system

Portable analysers

System integration

As a system integration company AquaGas offers a large range of engineering services including product and systems design, project management and consulting.

Onsite services

AquaGas provides a comprehensive and flexible range of onsite services covering preventive and corrective maintenance, calibrations, data processing and reporting.

ONSITE